SP600 AC Drive User Manual

Displays the present operating status of the drive.

210

Drive Status 2

Range:

See figure12.31

Default:

Read Only

Access:

2

Path: Utility>Diagnostics

See also:

209

Figure 12.31 – Drive Status 2 (210)

0

0

0

0

0

0

0

x

0

0

0

0

0

0

x

x

10

0

1

2

3

4

5

6

7

8

9

11

12

13

14

15

1 =Condition True
0 =Condition False
x =Reserved

Bit #

Ready

Active

Running

Jogging

Stopping

DC Braking

AutoT

uning

AutoRst Ctdn

AutoRst Act

Curr Limit

Bus Freq Reg

Motor Overld

DPI at 500 k

Nibble 1

Nibble 2

Nibble 3

Nibble 4

Bit Name

Description

0

Ready

No start inhibits are active.

1

Active

Drive is generating output voltage to the motor.

2

Running

Drive is generating output voltage to the motor, run has
been selected.

3

Jogging

Drive is in jog mode.

4

Stopping

Drive is stopping.

5

DC Braking

DC braking is active.

6

Auto Tuning

Tuning function is active.

8

AutoRst Ctdn

Auto Restart Countdown. Refer to parameter 174.

9

AutoRst Ac

Auto Restart Active. Refer to parameter 174.

10

Curr Limit

Drive is in current limit.

11

Bus Freq Reg

Drive is regulating bus frequency.

12

Motor Overld

Motor overload is active.

13

DPI @ 500 K

DPI communications is operating at 500 kbaud (1),
125 kbaud (0)

Advertising