1.2 Confirmations Upon Delivery

20

YASKAWA TM.iQp.06 iQpump Controller User Manual

Drive Model Numbers

The model number on the nameplate indicates the design specification, voltage, and rating of the iQpump drive in alphanumeric codes.

Figure 1.2 iQpump Drive Model Number Structure

Drive Enclosure and Revision Code

The iQpump drive SPEC number on the nameplate indicates the voltage, iQpump drive rating, enclosure type, and the revision code of

the iQpump drive in alphanumeric codes.

Figure 1.3 SPEC Number Structure

TERMS

TERMS

TERMS

Open Chassis Type (IEC IP00)

Protected so that parts of the human body cannot reach electrically charged parts from the front when

the iQpump drive is mounted in a control panel, also called (protected chassis).

TERMS

TERMS

TERMS

NEMA Type 1 (IEC IP20)

The iQpump drive is shielded from the exterior, and can thus be mounted to the interior wall of a
building (not necessarily enclosed in a control panel). The protective structure conforms to the

standards of NEMA Type 1 in the USA. All protective covers (Fig 1.4) must be installed to conform
with IEC IP20 and NEMA Type 1 requirements

No.

Spec

UL Specification

CIMR – P7 U 2 0 11*

AC Drive

U

No.

Voltage

2
4

3-phase, 208-240 Vac

3-phase, 480 Vac

Rating

iQpump Family

* YEA Item #: CIMR-P7U20111A-107

2 011 1 A U890107

No.

2
4

Voltage

3-phase, 208 - 240 Vac

3-phase, 480 Vac

No.

Enclosure Type

0

Open chassis (IEC IP00)

1

NEMA Type 1 (IEC IP20)

Hardware Revision

Rating