Removing/Attaching the Digital Operator and Front Cover

Models CIMR-P7U20P4 through 2018 (0.5 HP to 25 HP @ 208 V / 240 V) and

40P4 through 4018 (0.5 HP to 30 HP @ 480 V)

For Models CIMR-P7U2018 / 4018-107 and smaller, remove the terminal cover and use the following procedures to remove the digital

operator and front cover.

Removing the Digital Operator

Press on the side of the digital operator in the direction of arrow 1 to unlock, then lift the digital operator in the direction of arrow 2 to
remove it as shown in

Figure 1.15

.

Figure 1.15 Removing the Digital Operator

Removing the Front Cover

Press the left and right sides of the front cover in the direction of arrows 1 and lift the bottom of cover in the direction of arrow 2 to

remove it as shown in

Figure 1.16

.

Figure 1.16 Removing the Front Cover

Attaching the Front Cover

Mount the front cover to the iQpump drive by performing the steps to remove the front cover in reverse order.

1. Do not mount the front cover with the digital operator attached to the front cover; this may cause the digital operator to malfunction

due to imperfect contact.

2. Insert the tab of the upper part of the front cover into the groove of the iQpump drive and press the lower part of the front cover onto

the iQpump drive until the front cover snaps into place.