Yaskawa iQpump Controller User Manual User Manual

Page 4

Advertising
background image

4

YASKAWA TM.iQp.06 iQpump Controller User Manual

Table 1.2 Pump Quick Setup

Original Quick Start Menu

PRG: 0033

(VSP130033 and below)

New Quick Start Menu

PRG: 0034

(VSP130034 and above)

Parameter No.

Parameter Name

Parameter No.

Parameter Name

b1-01

Frequency Reference Selection
Reference Source

REMOVED FROM QUICK START MENU

b1-02

Run Command Selection
Run Source

REMOVED FROM QUICK START MENU

b5-12

PI Feedback Reference Missing Detection Selection
Fb los Det Sel

REMOVED FROM QUICK START MENU

b5-13

PI Feedback Loss Detection Level
Fb los Det Lvl

REMOVED FROM QUICK START MENU

b5-14

PI Feedback Loss Detection Time
Fb los Det Time

REMOVED FROM QUICK START MENU

C1-01

Acceleration Time
Accel Time 1

REMOVED FROM QUICK START MENU

C1-02

Deceleration Time
Decel Time 1

REMOVED FROM QUICK START MENU

d1-01

Start Level Delay Time
S-Lvl Delay Time

E2-01

Motor Rated Current
Motor Rated FLA

E2-01

Motor Rated Current
Motor Rated FLA

E2-04

Number of Motor Poles
Number of Poles

E2-04

Number of Motor Poles
Number of Poles

L5-01

Number of Auto Restart Attempts
Num of Restarts

REMOVED FROM QUICK START MENU

L5-03

Maximum Restart Time After Fault
Max Restart Time

REMOVED FROM QUICK START MENU

P1-02

System Units
System Units

REMOVED FROM QUICK START MENU

P1-03

Feedback Device Scaling
Fb Dev Scaling

P1-03

Feedback Device Scaling
Fb Dev Scaling

P1-04

Start Level
Start Level

P1-04

Start Level
Start Level

P1-05

Start Level Delay Time
S-Lvl Delay Time

REMOVED FROM QUICK START MENU

P1-07

Low Feedback Level
Low Fb Lvl

REMOVED FROM QUICK START MENU

P1-08

Low Feedback Level Fault Delay Time
Low Lvl FLT Time

REMOVED FROM QUICK START MENU

P1-09

High Feedback Level
High Fb Lvl

REMOVED FROM QUICK START MENU

P1-10

High Feedback Level Fault Delay Time
Hgh Lvl FLT Time

REMOVED FROM QUICK START MENU

P1-11

Maximum Set-point Difference
Max Set-point Diff

REMOVED FROM QUICK START MENU

P1-12

Not Maintaining Set-point Time
Not Maint SP Tm

REMOVED FROM QUICK START MENU

P1-14

Prime Loss Level
Prime Loss Lvl

REMOVED FROM QUICK START MENU

P2-01

Sleep Level Type
Sleep Lvl Type

REMOVED FROM QUICK START MENU

P2-02

Sleep Level
Sleep Level

REMOVED FROM QUICK START MENU

P2-03

Start Delay Time
Sleep Delay Time

REMOVED FROM QUICK START MENU

P2-10

Maximum Set-point Compensation
Max SP Comp

REMOVED FROM QUICK START MENU

P4-01

Pre-charge Level
Pre-charge Level

REMOVED FROM QUICK START MENU

P4-02

Pre-charge Frequency
Pre-charge Freq

REMOVED FROM QUICK START MENU

Advertising