Figure 8-9. result of s – Hitachi GR2000 Series User Manual

Page 272

Advertising
background image

Hitachi Gigabit Router GR2000 Series Enhanced Version Operations - Device Management Overview

8-10

GR2K-GA-0015

Ver. 07-02

Step 1.

Configure-off the standby BCU.

From the device management terminal connected to the active side of the
router, enter

show router

command and confirm the status of the standby

system.

> show router [CR]

Figure 8-9 shows the command execution result, where “rm0” is the active
system and “rm1” is the standby system.

Figure 8-9 Result of show router Command

(a) When the standby BCU turns out to be failing:

When the standby BCU fails, its status becomes “fault.” In this case, from
the operation terminal connected to the operation system, enter the
command shown below.

> close standby [CR]

After entering this command, remove the standby BCU in accordance with
Step 2 shown below.

(b) When swapping the CPU fan:

When the CPU fan is to be swapped, confirm that the status of the standby
BCU is other than “fault.” Enter the command shown below.

> close standby [CR]

Make sure that the STATUS LED of the standby BCU’s RM-I/O board is lit
yellow. Then, remove the standby BCU in accordance with Step 2 shown
below.

> show router

router: GR2000 S-9181-11 01-01 [ROUTE-OS] , standard model

node : name=System Name

contact=Contact Address

locate=Location

: : : : : :

rm0 : active

rm : HN-F9533-5M3 [BCU-M300] 0000

boot : 10/10 20:10:34 , power on , 0 times restart

: : : : : :

rm1 : fault

: : : : : :

Status of the standby system.

Advertising