Hitachi GR2000 Series User Manual

Page 302

Advertising
background image

Hitachi Gigabit Router GR2000 Series Enhanced Version Operations - Device Management Overview

8-40

GR2K-GA-0015

Ver. 07-02

For example, to test line No. 0 of NIF No. 1, enter the command lines as shown
below:

> test interfaces nif 1 line 0 connector [CR]

(Wait about 1 minute.)

> no test interfaces nif 1 line 0 [CR]

The result will appear in a similar manner as (a) internal loopback test for WAN
line.Make sure that “Send-NG” and “Receive-NG” are both 0

.

(3) Modem Manual Loopback Test for WAN Line

The testing can be executed on modem-connected serial lines (V.24/V.35/X.21)
by entering the

test interfaces

and

no test interfaces

commands from the device

management terminal.

This test loops back the test frame at the local modem or remote modem set to
loopback mode. Prior to testing, the modem should be set to loopback mode.For
example, to test line No. 0 of NIF No. 1, enter the command lines as shown below:

> test interfaces nif 1 line 0 manual [CR]

(Wait about 1 minute.)

> no test interfaces nif 1 line 0 [CR]

If “Test Count” is not 0 and either “Send-NG” or “Receive-NG” is not 0, analyze
the result in accordance with (a) Internal Loopback Test for WAN Line.

(4) Local Modem Loopback Test (LLB) for WAN Line:

This test loops back the test frame at the local modem in support of local modem
loopback test. The testing can be executed on modem-connected V.24 serial lines
(not V.35 or X.21) by entering the

test interfaces

and

no test interfaces

commands

from the device management terminal. For example, to test line No. 0 of NIF No.1,
enter the command lines as shown below:

> test line interfaces nif 1 line 0 local [CR]

(Wait about 1 minute.)

> no test interfaces nif 1 line 0 [CR]

If “Test Count” is not 0 and either “Send-NG” or “Receive-NG” is not 0, analyze
the result in accordance with (a) Internal Loopback Test for WAN Line.

*

Note: The test can be executed on the NIF boards OC-3c (8 ports), OC-12c (4 ports), and OC-48c

only when the clock of the configuration definition information line is set to “independent.”
If the clock is set to “external,” a line fault is likely to occur.

*

Note: The result will appear in a similar manner as (a) internal loopback test for WAN line.Make

sure that “Send-NG” and “Receive-NG” are both 0(normal) and “Test Count” is not 0. If
“Test Count” is 0, confirm the line status using of the show interfaces
(serial)

information

in GR2000 Operations Commands, Vol. 1.

*

Note: The result will appear in a similar manner as internal loopback test for WAN line.Make sure

that “Send-NG” and “Receive-NG” are both 0(normal) and “Test Count” is not 0. If “Test
Count” is 0, confirm the line status using the information of the show interfaces
(serial)

information in GR2000 Operations Commands, Vol. 1

.