3.2.14

Device Operation Messages

When the device’s status has changed, a device operation message appears on the
console or remote terminal. For example, a recovery message appears if a line is
recovered from a failure, and an error message appears when operation is suspended
with a line failure.

For more information, see the GR2000 Operations Log and MIB Reference. If the shell
program is running or the load is heavy, there may be an instance where a device
operation message exists but is not displayed. In such a case, check the log
information where all device operation messages are recorded.

3.2.15

Automatic Logout

If a key entry is not made within a certain period (default: 60 minutes) during the CLI
actuation, logout is performed automatically. The automatic logout time can be
changed by using

set exec-timeout

.

Table 3-3 Warning Messages

Message Contents

mc0 is disabled

Use of MC 0 prohibited; you may not be able to perform normal
operations.

mc1 is disabled

Use of MC 1 prohibited; you may not be able to perform normal
operations.

This router is restarted by pressing
default-restart-switch.

The device has been started with default restart. Be careful, since
the password security check is disabled.

Version mismatch between active
and standby software detected.

Software version differs between operating system and standby
system. Be careful, the duplexed configuration is disabled.

Date mismatch between active and
standby configuration files
detected.

Configuration definition information differs between the operating
system and standby system. Be careful, the duplexed
configuration is disabled.
If configuration definitions are copied in the active MC in current
use in devices operated in duplicate, this may be indicated due to
temporary differences in definition configuration data in the active
and standby systems.

NIF <NIF No.> Line <Line No.> is
under line-test.

The specified line is under test and is not available for
communication.

<NIF No.>:

NIF number

<Line No.>:

Line number

NIF <NIF No.> Line <Line No.>
subline <Subline No.> is under
line-test

<Subline No.>:

Subline number