Operation during initial installation

GR2K-GA-0015

4-9

Ver. 07-02

4.5

Setting the configuration definition information

4.5.1

Overview

Define the operational environment (type of network media connected to the outer or
the routing protocol used) of the outer in configuration definition information when
operation starts. The configuration definition information can be defined using a
configuration definition command or on the Web browser screen. See the
Configuration Guide for the description of configuration definition information or the
specifications of a parameter. The Configuration Guide also describes the method of
operation of a current/preliminary configuration definition information file or the
setting and operation examples of configuration definition information.

4.5.2

Precautions during duplex operation

Whether active and standby operational configuration definition information items
are the same during router start and during configuration definition setting when the
outer is duplex-operated is checked. The failure log below is output if the active and
standby operational configuration definition information items are different.

E5 CONFIG 00010002 0100:000000000000 Standby system is unavailable to be

swapped when active system fails

because of configuration file

mismatch between active and standby.

Correct configuration file of standby

system.

In this case, 01 lights in STATUS CODE and the EMA SUPPRESS LED indicator
lights in yellow. (See Operation Log and MIB Reference, 1. LED display and viewing
the fault code, for STATUS CODE and EMA SUPPRESS LED.) In this case, no mode
switching is executed to prevent the inconsistency of operation caused by mode
switching even if a fatal failure occurs in the active mode or a swap rm command is
executed in the active mode. Once this failure log is output, the suppression of mode
switching cannot be released even if the active operational configuration definition
information is set again according to the standby operational configuration
definition. To switch the active mode, make the active operational configuration
definition information coincide with the standby operational configuration definition
information using a configuration definition command (CLI type 1) (save) or (copy).
(See GR2000 Configuration Settings, for details of an execution example.) The
standby mode is automatically restarted when a configuration definition command
(CLI type 1) (copy) is executed. After the standby mode is restarted, confirm that the
failure log occurring when the operational configuration definition information items
described above are different is not output again.