Figure 8-14 Startup Slot Initialization Method

If the ROM date based on the

version

command in the procedure of Figure 8-14 is

later than Sep 20 11:18:01 2000 JST, execute the

modeset reset boot

command and

initialize the startup slot setting. Accurately reenter if the display results indicated in
Figure 8-14 are not obtained after executing the

modeset

command.

Step 5.

Configure-on the standby BCU:

Swapping only the standby BCU does not cause the standby BCU to act as
a backup system in a duplexed configuration. After performing Step 4, you
must enter the command shown below from the device management
terminal connected to the active side.

> free standby [CR]

Confirm that the EMA SUPPRESS LED on the RM-I/O board of both
systems is not lit and the operation status of the standby system is
standby. To confirm standby system operation status, enter the

show router

command shown below from the operation terminal connected to the
operation system.

> show router [CR]

Figure 8-15 shows the

show router

command results.

Figure 8-15 Result of show router Command

For ROUTE-OS7, restart an MPLS program in standby BCU using a restart mpls
command after confirming that standby BCU has been put into the active state
(normal duplex operational state). See Application Guide for details. [ROUTE-OS7]

Rom: version

ROM: 03-02 Rev2 Wed Sep 20 11:18:01 2000 JST

BIOS Rev.:R1.02.E4 (990129)

Rom: modeset reset boot

1st boot device is default device(same as MC slot#0)

Shows ROM version. If the ROM date
based on the "version" command is later
than Sep 20 11:18:01 2000JST, execute
the modeset reset boot command

Execute the startup slot initialization

It is confirming that the startup slot is setting on slot 0

> show router

router: GR2000 S-9181-11 01-01 [ROUTE-OS] , standard model

node : name=System Name

contact=Contact Address

locate=Location

: : : : : :

rm0 : active

rm : HN-F9533-5M3 [BCU-M300] 0000

boot : 10/10 20:10:34 , power on , 0 times restart

: : : : : :

rm1 : standby

rm : HN-F9533-11 [BCU-M300] 0000

boot : 10/10 20:12:34 , power on , 0 times restart

: : : : : :

The operation status of the standby system
must be standby.