6 status assurances on bcu/rp/nif and lines, 1 assurance on standby bcu newly added or swapped, 2 assurance on rp and nif newly added or swapped – Hitachi GR2000 Series User Manual

Page 295: 6 status assurances on bcu/rp/nif and lines -33, Figure 8-34. result of information command -33

Advertising
background image

Maintenance Procedure

GR2K-GA-0015

8-33

Ver. 07-02

8.6

Status Assurances on BCU/RP/NIF and Lines

8.6.1

Assurance on Standby BCU Newly Added or Swapped

This procedure applies to daily monitoring, post-maintenance or post-upgrade
checkout, or error handling relating to BCUs (including CPU fans).

First, enter

show router

command from the device management terminal connected to

the active side.

> show router [CR]

The result will appear as in Figure 8-34 where you find the status of the standby
BCU. In this example, “rm0” is the active BCU and “rm1” is the standby BCU.

Figure 8-34 Result of information Command

The following are the possible statuses for the standby BCU:

(a)

standby

. The status is normal.

(b)

fault.

The standby BCU is faulty or being initialized. The latter can be

identified by the STATUS LED blinking green. If not, execute the

show logging

command to obtain detailed information on the standby BCU.

(c)

close

. The standby BCU is under maintenance and duplex operation is

temporarily disabled. When maintenance is complete, enter the following
command from the device management terminal connected to the active BCU:

>

free standby [CR]

(d)

disconnect

. Standby BCU (RM-I/O, RM-CPU, or CSW) is disconnected.

(e)

configuration discord

. The configuration information of the active BCU and

that of the standby BCU do not match, disabling normal duplex operation. To
resolve the configuration information mismatch, see Subsection 4.5.2,
“Precautions during duplex operation”.

(f)

software version discord

. The software versions of the active BCU and those

of the standby BCU do not match, disabling normal duplex operation. Resolve
the software version mismatch.

8.6.2

Assurance on RP and NIF Newly Added or Swapped

Procedures exemplified below apply to daily monitoring, post-maintenance or
post-upgrade checkout, or error handling relating to RPs and NIFs.

> show router

router: GR2000 S-9181-11 01-01 [ROUTE-OS] , standard model

node : name=System Name

contact=Contact Address

locate=Location

: : : : : :

rm0 : active

rm : HN-F9533-5M3 [BCU-M300] 0000

boot : 10/10 20:10:34 , power on , 0 times restart

: : : : : :

rm1 : fault

: : : : : :

Operating status of standby system

Advertising