Maintenance Procedure

GR2K-GA-0015

8-11

Ver. 07-02

Step 2.

Remove the standby BCU.

Figure 8-10 shows the procedures for removing the standby BCU. Removing
the standby BCU must be performed in the order of RM-I/O, RM-CPU, and
CSW (GR2000-20H only).

Figure 8-10 Procedure for Removal of Standby BCU

!

WARNING: Hazardous voltage. Can cause death or severe injury. Removing/adding component

while power is on must be conducted by trained and qualified engineer or
maintenance personnel.

Remove the MC card installed on the standby BCU RM-I/O board.

Remove the RM-I/O board from the standby BCU.

Note: If the MC card is removed during MC access, it might fail;
check the MC card access LED.

Remove the RM-I/O board from the standby BCU.

Remove the CSW from the standby BCU.

Note:

The last step is required only for the GR2000-20H.