2 carrying out encoderless manual jogging, 11 basic drive functions – Lenze 9400 User Manual
Page 409
Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06
409
11
Basic drive functions
11.5
Manual job, encoderless
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
11.5.2
Carrying out encoderless manual jogging
The procedure for using this basic function is described with reference to the signal characteristic
shown below.
Please refer to the following chapters for more information
Selection and contents of the profile parameter set
Encoderless manual jogging in a positive/negative direction
[11-20] Signal characteristic: activation/deactivation of basic function "manual jog (OL)"
Resetting of MOL_bEnable is not permissible here
On activation:
1. MOL_bEnable = Low High
2.CINH = High Low
On deactivation:
1. CINH = Low High
2.MOL_bEnable = High Low
CINH
t
MOL_bEnable
t
t
t
MOL_bJogNegative
t
MOL_bJogPositive
t
I
Motor
t
f
d_Motor
t
I
PS1
I
PS3
I
PS1
f
d_PS1
f
d_PS3
?
MOL_bActivateDataBit1
MOL_bActivateDataBit2
0
1