2 carrying out encoderless manual jogging, 11 basic drive functions – Lenze 9400 User Manual

Page 409

Advertising
background image

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

409

11

Basic drive functions

11.5

Manual job, encoderless

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

11.5.2

Carrying out encoderless manual jogging

The procedure for using this basic function is described with reference to the signal characteristic

shown below.
Please refer to the following chapters for more information

Requirements

Activation

/

Deactivation

Selection and contents of the profile parameter set

Encoderless manual jogging in a positive/negative direction

[11-20] Signal characteristic: activation/deactivation of basic function "manual jog (OL)"

Resetting of MOL_bEnable is not permissible here

 On activation:

1. MOL_bEnable = Low  High

2.CINH = High  Low

 On deactivation:

1. CINH = Low  High

2.MOL_bEnable = High  Low

CINH

t

MOL_bEnable

t

t

t

MOL_bJogNegative

t

MOL_bJogPositive

t

I

Motor

t

f

d_Motor

t

I

PS1

I

PS3

I

PS1

f

d_PS1

f

d_PS3

?

MOL_bActivateDataBit1

MOL_bActivateDataBit2

0

1