11

Basic drive functions

11.5

Manual job, encoderless

412

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

11.5.2.4

Selection and contents of the profile parameter set

For controlled traversing, four different profiles can be parameterised. The profile parameter set to

be used is selected by means of the control inputs MOL_bActivateDataBit1

C02781/4

and

MOL_bActivateDataBit2

C02781/5

or alternatively by means of the parameters

C02770/4

(ActivateDataBit1) and

C02770/5

(ActivateDataBit2):

MOL_bActivateData

Bit2

C02781/5

MOL_bActivateData

Bit1

C02781/4

Selected profile parameter set

FALSE

FALSE

Profile parameter set 1

FALSE

TRUE

Profile parameter set 2

TRUE

FALSE

Profile parameter set 3

TRUE

TRUE

Profile parameter set 4

Setpoint

Profile parameter set

1

Profile parameter set

2

Profile parameter set

3

Profile parameter set

4

Frequency

C02771/1

C02771/2

C02771/3

C02771/4

Start angle

C02772/1

C02772/2

C02772/3

C02772/4

Current

C02773/1

C02773/2

C02773/3

C02773/4

Acceleration time

C02774/1

C02774/2

C02774/3

C02774/4

Deceleration time

C02775/1

C02775/2

C02775/3

C02775/4

Max. activation time

C02776/1

C02776/2

C02776/3

C02776/4

Note!

The four profile parameter sets must be dealt with sequentially, i.e. a selected profile

parameter set must first be completed with f

d

= 0 Hz before a further profile parameter

set can be activated.

• The signal characteristic in Fig.

[11-20]

( 409)

shows that the drive must ramp down

completely in the case of each parameter set before the next parameter set can be

started.

• Lenze recommends to control the basic function in accordance with this signal

characteristic.