11.13

Cam data management

568

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

11.13.5

Invalid cam data due to changed machine parameters

This function extension is available from software version V4.0!

If one or more machine parameters affecting the internal scaling of the cam data are changed, the

message "Cam Data: Invalidated due to change of mechanical data" (error number

0x00b80034

) is

entered into the logbook and the error response "Warning" occurs.

• The cam data are no longer valid and have to be recalculated.
• The warning is automatically reset if the

C00002

= "503: Calculate Cam Data" device command

is executed.

Calculate cam data

( 91)

Machine parameters affecting the internal scaling of the cam data:

Parameter

Info

C00006

Selection of the motor control

C00100

Resolution of an encoder revolution

C02520

/

C02521

Gearbox factor - motor (if motor = reference source)

C02522

/

C02523

Gearbox factor - position encoder (if position encoder = reference source)

C02524

Feed constant

C02570

Position control structure