Device commands

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

4.2.40

Calculate cam data

This function extension is available from software version V3.0!

The

C00002

= "503: Calculate cam data" device command converts the cam data stored in the main

memory of the controller to the internal format and makes them available to the application. This,

for instance, is necessary if one or more machine parameters affecting the internal scaling of cam

data have been changed.

• The status signal bNewDataAvailable of the basic drive function "

Cam data management

"

(LS_CamInterface system block) is set to TRUE and the cam data are accepted automatically or

manually depending on the online change mode set. After successful data acceptance, the

status signal bNewDataAvailable is automatically reset to FALSE.

• The user password does not have to be entered in

C02900

.

• While the function is executed, no online change and no change of the cam data via parameters

can be carried out.

• This function is executed in the background and can also be activated when the controller is

enabled and the application is running.

Tip!
Detailed information on the cam functionality can be found in the chapter "Basic drive

functions", subchapter "

Cam data management

".

( 552)

Possible status displays for this device command

Related device commands

Load cam data

( 87)

Save cam data

( 89)

Calculate cam data checksum

( 92)

Status (

C00003

)

Meaning

32998658 Device command in process

32964608 Device command executed successfully

32964609 General fault
33006617 The cam functionality is deactivated