38 load cam data, 4drive interface – Lenze 9400 User Manual

Page 87

Advertising
background image

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

87

4

Drive interface

4.2

Device commands

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

4.2.38

Load cam data

This function extension is available from software version V3.0!

The

C00002

= "501: Load cam data" device command serves to reload cam data from the memory

module into the controller.

[4-22] "Load cam data" function

• Only possible when the application has stopped and the controller is inhibited.
• If the cam data are provided with an access protection, the user password has to be entered in

C02900

first.

Tip!
Detailed information on the online change mode and the access protection can be found in

the chapter "Basic drive functions", subchapter "

Cam data management

".

( 552)

Sequence

1. The cam data are completely loaded from the memory module into the main memory of the

controller.

2. The present cam data in the application unit are converted to the internal unit [increments] and

are reorganised.

3. The processed cam data are stored in a separate main memory that can be accessed by the cam

application.

Note!

If you transfer the parameter set or the application from »Engineer« to the controller,

the cam data are also transferred automatically to the controller.

• The new/altered cam data are accepted in the controller according to the online

change mode set.

• Thus, normally this device command does not need to be executed manually.

9400

RAM

Memory module MM

Cam data

Cam data

Cam application

Advertising
This manual is related to the following products: