Ta" (error number, 0x00b80034, 0x00b80032 – Lenze 9400 User Manual

Page 711: 0x00b80033, 13 diagnostics & fault analysis

Advertising
background image

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

711

13

Diagnostics & fault analysis

13.7

Error messages of the operating system

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Int. overflow C02647 (homing: Acceleration 2) [0x00b80032]

Int. overflow C02670 (positioner: Tol. for target position) [0x00b80033]

Cam data: Invalidated due to change of mechanical data [0x00b80034]

Module ID (decimal)

Error ID (decimal)

184: Basic drive functions

50

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

From software version V3.0

Due to a subsequent change of the machine parameters

for gearbox ratio, feed constant, or resolution of an

encoder revolution, the value set in the parameter

cannot be displayed in the internal unit. See chapter

"

Max. position, speed, and acceleration that can be

displayed internally

".

• Check machine parameters and adapt them if

required.

• Change setting in

C02647

.

Module ID (decimal)

Error ID (decimal)

184: Basic drive functions

51

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

From software version V3.0

Due to a subsequent change of the machine parameters

for gearbox ratio, feed constant, or resolution of an

encoder revolution, the value set in the parameter

cannot be displayed in the internal unit. See chapter

"

Max. position, speed, and acceleration that can be

displayed internally

".

• Check machine parameters and adapt them if

required.

• Change setting in

C02670

.

Module ID (decimal)

Error ID (decimal)

184: Basic drive functions

52

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

From software version V4.0

One or several machine parameters have been changed

that have an influence on the internal scaling of the Cam

data. The Cam data has to be recalculated. See chapter

"

Invalid Cam data due to changed machine parameters

".

Execute device command

C00002

= "503: Calculate Cam

Data". This automatically resets the warning.