Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

599

13

Diagnostics & fault analysis

13.1

LED status displays

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

13.1.1

LED status displays for the device state

The control of the two LEDs "DRIVE READY" and "DRIVE ERROR" in the middle of the controller's front

panel depends on the device state.

Device states

( 97)

[13-2] DRIVE READY and DRIVE ERROR LED status displays

The meaning can be seen from the table below:

DRIVE READY

DRIVE ERROR

DRIVE READY

DRIVE ERROR

Meaning

OFF

OFF

"Initialisation active" state

OFF

"Safe torque off active" state

Observe LED on the safety module!

OFF

"Device is ready to switch on" state

OFF

"Device is switched on" state

OFF

"Operation" state

"Warning active"

or

"Warning locked active"

The controller is ready to switch on, switched on or the operation is

enabled and a warning is indicated.

"Quick stop by trouble active" state

OFF

"Trouble active" state

OFF

"Fault active" state

OFF

"System fault active" state

Legend

Meaning of the symbols used to describe the LED states:

LED is flashing once approx. every 3 seconds (slow flash)

LED is flashing once approx. every 1.25 seconds (flash)

LED is flashing twice approx. every 1.25 seconds (double flash)

LED is blinking every second

LED is permanently on