13

Diagnostics & fault analysis

13.5

Monitoring

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

13.5

Monitoring

The controller is provided with various monitoring functions which protect the drive against

impermissible operating conditions.

• If a monitoring function responds,

• an entry will be made into the

Logbook

of the controller,

• the response (quick stop by trouble, warning, fault, etc.) selected for this monitoring function

is activated,

• the status of the internal device control changes according to the selected response,

controller inhibit is set, and the "DRIVE ERROR" LED on the front of the controller goes on:

See also:

Device states

( 97)

LED status displays for the device state

( 599)

Response

Logbook entry

Display in

C00168

Pulse inhibit

Controller inhibit

Acknowledgeme

nt required

LED

"DRIVE ERROR"

None

OFF

Information

OFF

Warning

Warning locked

Quick stop by

trouble

Trouble

(after 0.5 s)

Fault

System fault

Mains

switching

is required!

Danger!

If automatic restart is enabled (

C00142

= "1: Enabled"), the drive can restart

automatically from the "Trouble" and "Safe torque off" device states when the trouble or

request for "Safe torque off active" has been eliminated!

Automatic restart after mains connection/trouble...