Negative direction of rotation limited [0x00b8000a, Speed has been limited [0x00b8000b, Acceleration has been limited [0x00b8000c – Lenze 9400 User Manual

Page 700: Deceleration has been limited [0x00b8000d, 0x00b8000c, 0x00b8000d, 0x00b8000a, 0x00b8000b, 13 diagnostics & fault analysis

Advertising
background image

13

Diagnostics & fault analysis

13.7

Error messages of the operating system

700

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Negative direction of rotation limited [0x00b8000a]

Speed has been limited [0x00b8000b]

Acceleration has been limited [0x00b8000c]

Deceleration has been limited [0x00b8000d]

Module ID (decimal)

Error ID (decimal)

184: Basic drive functions

10

Response (Lenze setting printed in bold)

Setting:

C02716/1

( Adjustable response)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

Due to the setting of

C02707

it was tried to traverse in

the impermissible negative direction of rotation.

• Only traverse in permissible (positive) direction of

rotation.

• Change setting of the permissible direction of

rotation (

C02707

).

Module ID (decimal)

Error ID (decimal)

184: Basic drive functions

11

Response (Lenze setting printed in bold)

Setting:

C02716/3

( Adjustable response)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

• The requested profile speed is higher than the

maximum speed set in

C02703

and has been limited

to this speed.

• The required profile speed cannot be achieved with

the motor reference speed set in

C00011

.

• Reduce speed of the traversing profile of the basic

function (manual jog, homing, or positioning).

• Increase maximum speed (

C02703

).

• Deactivate monitoring of the limit values by the basic

function "Limiter".

• Set motor reference speed correctly (

C00011

).

Module ID (decimal)

Error ID (decimal)

184: Basic drive functions

12

Response (Lenze setting printed in bold)

Setting:

C02716/3

( Adjustable response)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

The requested profile acceleration is higher than the

maximum acceleration set in

C02705

and has been

limited to this acceleration.

• Reduce acceleration of the traversing profile of the

basic function (manual jog, homing, or positioning).

• Increase maximum acceleration (

C02705

).

• Deactivate monitoring of the limit values by the basic

function "Limiter".

Module ID (decimal)

Error ID (decimal)

184: Basic drive functions

13

Response (Lenze setting printed in bold)

Setting:

C02716/3

( Adjustable response)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

The requested profile deceleration is higher than the

maximum acceleration set in

C02705

and has been

limited to this acceleration.

• Reduce acceleration of the traversing profile of the

basic function (manual jog, homing, or positioning).

• Increase maximum acceleration (

C02705

).

• Deactivate monitoring of the limit values by the basic

function "Limiter".

Advertising