4.2.25

Determine motor parameters

The

C00002

= "72: Determine motor parameters" device command is used to automatically

determine the motor parameters for a third-party motor that are listed in the following table – if

they are not known:

Tip!
Detailed information about the automatic determination of the motor parameters can be

found in the chapter "Motor interface" in the subchapter "

Determining the motor

parameters

".

( 138)

Possible status displays for this device command

Parameter

Info

ASM

SM

C00079

Mutual motor inductance

C00082

Motor rotor resistance

C00084

Motor stator resistance

C00085

Motor stator leakage inductance

C00091

Motor cosine phi

C00092

Motor magnetising current

Status (

C00003

)

Meaning

4752642 Device command in process

4718592 Device command executed successfully

4718593 General fault
4758290 Motor identification cannot be started since the current controller test mode is active.
4758291 Motor identification cannot be started since the V/f test mode is active.
4758292 Motor identification cannot be started because pole position identification is active.
4758293 Motor identification has been aborted.
4758294 Motor identification has been aborted by fault.
4758332 Motor identification aborted due to inconsistent motor parameters.

This error message is only available from software version V7.0 onwards.