Int. overflow c02644 (homing: speed 1) [0x00b8002f, Int. overflow c02646 (homing: speed 2) [0x00b80031, 0x00b8002f – Lenze 9400 User Manual

Page 710: 0x00b80030, 0x00b80031, 13 diagnostics & fault analysis

Advertising
background image

13

Diagnostics & fault analysis

13.7

Error messages of the operating system

710

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Int. overflow C02644 (homing: Speed 1) [0x00b8002f]

Int. overflow C02645 (homing: Acceleration 1) [0x00b80030]

Int. overflow C02646 (homing: Speed 2) [0x00b80031]

Module ID (decimal)

Error ID (decimal)

184: Basic drive functions

47

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

From software version V3.0

Due to a subsequent change of the machine parameters

for gearbox ratio, feed constant, or resolution of an

encoder revolution, the value set in the parameter

cannot be displayed in the internal unit. See chapter

"

Max. position, speed, and acceleration that can be

displayed internally

".

• Check machine parameters and adapt them if

required.

• Change setting in

C02644

.

Module ID (decimal)

Error ID (decimal)

184: Basic drive functions

48

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

From software version V3.0

Due to a subsequent change of the machine parameters

for gearbox ratio, feed constant, or resolution of an

encoder revolution, the value set in the parameter

cannot be displayed in the internal unit. See chapter

"

Max. position, speed, and acceleration that can be

displayed internally

".

• Check machine parameters and adapt them if

required.

• Change setting in

C02645

.

Module ID (decimal)

Error ID (decimal)

184: Basic drive functions

49

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

From software version V3.0

Due to a subsequent change of the machine parameters

for gearbox ratio, feed constant, or resolution of an

encoder revolution, the value set in the parameter

cannot be displayed in the internal unit. See chapter

"

Max. position, speed, and acceleration that can be

displayed internally

".

• Check machine parameters and adapt them if

required.

• Change setting in

C02646

.

Advertising