3 attribute table, 14 parameter reference – Lenze 9400 User Manual

Page 913

Advertising
background image

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

913

14

Parameter reference

14.3

Attribute table

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

14.3

Attribute table

The table of attributes contains information required for a communication with the controller via

parameters.

How to read the table of attributes:

Column

Meaning

Entry

Code

Parameter name

Cxxxxx

Name

Parameter short text (display text)

Text

Type

Parameter type

Selection list

Value from selection list

Bit coded

Bit coded value

Linear value

Value with setting range

String

String

Index

dec

Index under which the parameter is addressed.

The subindex for array variables corresponds to the

Lenze subcode number.

24575 - Lenze code number

Is only required for access via a bus

system.

hex

5FFF

h

- Lenze code number

Data

DS

Data structure

E

Single variable

(only one parameter element)

A

Array variable

(several parameter elements)

DA

Number of array elements (subcodes)

Number

DT

Data type

BITFIELD_8

1 byte bit-coded

BITFIELD_16

2 bytes bit-coded

BITFIELD_32

4 bytes bit-coded

INTEGER_8

1 byte with sign

INTEGER_16

2 bytes with sign

INTEGER_32

4 bytes with sign

UNSIGNED_8

1 byte without sign

UNSIGNED_16

2 bytes without sign

UNSIGNED_32

4 bytes without sign

VISIBLE_STRING [xx]

ASCII string (with character length xx)

Factor

Factor for data transmission via a bus system,

depending on the number of decimal positions

Factor

1 ≡ no decimal positions

10 ≡ 1 decimal position

100 ≡ 2 decimal positions

1000 ≡ 3 decimal positions

10000 ≡ 4 decimal positions

CINH

Writing is only possible if the controller is inhibited CINH

Code

Name

Type

Index

Data

dec

hex

DS

DA

DT

Factor

CINH

C00002

Device commands

Selection list

24573

5FFD

E

1

UNSIGNED_32

1

C00003

Device command status

Linear value

24572

5FFC

E

1

UNSIGNED_32

1

C00004

Service password

Linear value

24571

5FFB

E

1

UNSIGNED_32

1

C00005

Application selection

Linear value

24570

5FFA

E

1

INTEGER_32

1

C00006

Select motor control

Selection list

24569

5FF9

E

1

UNSIGNED_32

1 CINH

C00007

Active application

Linear value

24568

5FF8

E

1

INTEGER_32

1

C00008

Device command progress

Linear value

24567

5FF7

E

1

UNSIGNED_32

1

C00011

Motor reference speed

Linear value

24564

5FF4

E

1

UNSIGNED_32

1

C00018

Switching frequency

Selection list

24557

5FED

E

1

UNSIGNED_32

1

C00019

Threshold - standstill recognition

Linear value

24556

5FEC

E

1

UNSIGNED_32

1

C00022

Maximum current

Linear value

24553

5FE9

E

1

UNSIGNED_32

100

C00034

Config. analog input 1

Selection list

24541

5FDD

E

1

UNSIGNED_32

1

C00050

Speed setpoint [rpm]

Linear value

24525

5FCD

A

2

INTEGER_32

1

C00051

Actual speed [rpm]

Linear value

24524

5FCC

E

1

INTEGER_32

1

Greyed out = display parameter (read only access)

Advertising