Starting Up Your System

6-7

Starting Up Your System

Once you are familiar with the HIM, you can begin the start up
procedure.

Figure 6.4 shows the outline for the start up procedure for the
1336 IMPACT drive.

Figure 6.4
Start Up Procedure

This start up procedure is designed to be a fast, basic start up. It does
not address all available functions and options. You should use this
start up procedure to get your basic system running and then adjust
any remaining parameters that you need for your particular
application.

!

ATTENTION: During the start up procedures, the
motor will rotate. Hazard of personal injury exists due
to unexpected starts, rotation in the wrong direction, or
contact with the motor shaft.

If possible, uncouple the motor from the load and place
a guard around the motor shaft.

Make sure the motor is securely mounted before
beginning this procedure.

Startup

Quick Motor Tune?

Enter Motor Data?

Encoder?

Regen/Brake?

Phase Rotation?

Autotune?

Inductance
Resistance

Flux Current

Inertia

Configure Analog

Section?

Inputs

Outputs

Configure Digital

Section?

Relay Output

Done

L Option

No

No

No