11-32

Parameters

95

Test Select 2

Test Select 2 is a diagnostic tool that you can use to access
specific testpoints. The value you enter specifies which data
values should be displayed in Test Data 2 (parameter 94). For
Test Select 2 values of 11100 through 11232, you need to first
enter a 111xx value to determine the number of hours since
power up, and then enter a 112xx value to determine the number
of minutes and seconds since power up.

Parameter number

95

File:group

Monitor:Testpoints

Fault Setup:Testpoints

Parameter type

linkable destination

Display

x

Factory default

0

Minimum value

0

Maximum value

65535

Conversion

1 = 1

If you enter this value for

Test Select 2 (parameter 95):

Then, the value in Test Data 2 (parameter 94) represents the:

9728

Scaled version of Torque Ref 1 (parameter 69)

9730

Sum of scaled Torque Ref 1 (parameter 69) and PTrim Output (parameter 48)

9987

Upper current limit (4096 @ rated motor positive current)

9988

Lower current limit (-4096 @ rated motor negative current)

9990

Upper torque limit (4096 @ rated motor positive torque)

9991

Lower torque limit (-4096 @ rated motor negative torque)

10000

Motor Flux % (parameter 88) limited to Min Flux Level (parameter 71)

10264

Value of Logic Input Status (par 14) at the time of the last stop event.

10503

Parameter limit conditions

10504

Parameter limit conditions

10505

Speed reference math limits

10506

Speed feedback math limits

10507

Speed regulator math limits

10508

Torque reference math limits

10509

Process trim math limits

hours

minutes/seconds

11100

11200

Realtime accumulated since power up

11101

11201

The time since power up that the fault in position 1 occurred

11102

11202

The time since power up that the fault in position 2 occurred

11103

11203

The time since power up that the fault in position 3 occurred

11104

11204

The time since power up that the fault in position 4 occurred

11105

11205

The time since power up that the fault in position 5 occurred

11106

11206

The time since power up that the fault in position 6 occurred

11107

11207

The time since power up that the fault in position 7 occurred

11108

11208

The time since power up that the fault in position 8 occurred

11109

11209

The time since power up that the fault in position 9 occurred

11110

11210

The time since power up that the fault in position 10 occurred

11111

11211

The time since power up that the fault in position 11 occurred

11112

11212

The time since power up that the fault in position 12 occurred

11113

11213

The time since power up that the fault in position 13 occurred

11114

11214

The time since power up that the fault in position 14 occurred

11115

11215

The time since power up that the fault in position 15 occurred

11116

11216

The time since power up that the fault in position 16 occurred

11117

11217

The time since power up that the fault in position 17 occurred

11118

11218

The time since power up that the fault in position 18 occurred

11119

11219

The time since power up that the fault in position 19 occurred

11120

11220

The time since power up that the fault in position 20 occurred

11121

11221

The time since power up that the fault in position 21 occurred

11122

11222

The time since power up that the fault in position 22 occurred

11123

11223

The time since power up that the fault in position 23 occurred