Parameters

11-33

If you enter this value for Test

Select 2 (parameter 95):

Then, the value in Test Data 2 (parameter 94) represents the:

hours

minutes/seconds

11124

11224

The time since power up that the fault in position 24 occurred

11125

11225

The time since power up that the fault in position 25 occurred

11126

11226

The time since power up that the fault in position 26 occurred

11127

11227

The time since power up that the fault in position 27 occurred

11128

11228

The time since power up that the fault in position 28 occurred

11129

11229

The time since power up that the fault in position 29 occurred

11130

11230

The time since power up that the fault in position 30 occurred

11131

11231

The time since power up that the fault in position 31 occurred

11132

11232

The time since power up that the fault in position 32 occurred

58144

Drive software version (example: 101)

58146

Drive power structure type

58220

Speed regulator output

58228

Speed error (reference — feedback)

58230

Unfiltered speed feedback (4096 @ Nameplate RPM)

58250

Internal torque reference (4096 @ rated motor torque)

58296

Inverter temperature feedback (degrees Celsius)

96

An In 1 Value

Use An In 1 Value to view the converted analog value of the input
at analog input 1.

Parameter number

96

File:group

Interface/Comm:Analog Inputs

Parameter type

source

Display

±x

Factory default

not applicable

Minimum value

-32767

Maximum value

+32767

Conversion

1 = 1

97

An In 1 Offset

Use An In 1 Offset to set the offset applied to the raw analog
value of the analog input 1 before the scale factor is applied. This
lets you shift the range of the analog input.

Parameter number

97

File:group

Interface/Comm:Analog Inputs

Parameter type

linkable destination

Display

±x.xxx volts

Factory default

0.000 volts

Minimum value

-19.980 volts

Maximum value

+19.980 volts

Conversion

205 = 1.000

98

An In 1 Scale

Use An In 1 Scale to set the scale factor or gain for analog
input 1. The value of analog input 1 is converted to +2048 and
then the scale is applied. This provides an effective digital range
of

±32767.

Parameter number

98

File:group

Interface/Comm:Analog Inputs

Parameter type

linkable destination

Display

±x.xxx

Factory default

+2.000

Minimum value

-16.000

Maximum value

+16.000

Conversion

2048 = 1.000

99

An In 2 Value

Use An In 2 Value to view the converted analog value of the input
at analog input 2.

Parameter number

99

File:group

Interface/Comm:Analog Inputs

Parameter type

source

Display

±x

Factory default

not applicable

Minimum value

-32767

Maximum value

+32767

Conversion

1 = 1