11-16

Parameters

21

Warning Select 1

Use Warning Select 1 to specify how the drive should handle
certain conditions. Each bit within this parameter matches the bit
definitions of Fault Select 1 (parameter 20). If you set a bit to 1
and the corresponding bit in Fault Select 1 is clear (0), the drive
reports a warning when that condition occurs. If both
corresponding bits in Fault Select 1 and Warning Select 1 are 0,
the drive ignores the condition when it occurs.

The bits are defined as follows:

Parameter number

21

File:group

Fault Setup:Fault Config

Parameter type

linkable destination

Display

bits

Factory default

00000000.00011100

Minimum value

00000000.00000000

Maximum value

01111111.00111111

Conversion

1 = 1

Refer to Chapter 12, Troubleshooting, for additional information.

Bit

Description

0

RidethruTime
A bus ridethrough timeout
occurred.

1

Prechrg Time
A bus precharge timeout
occurred.

2

Bus Drop
A bus drop of 150 volts occurred.

3

Bus Undervlt
A bus undervoltage occurred.

4

Bus Cycles>5
More than 5 ridethroughs
occurred in a row.

5

Open Circuit
Fast flux up current is <50%.

Bit

Description

6 – 7

Reserved
Leave 0.

8

mA Input
A loss of input connection
occurred after it was established.

9

SP 1 Timeout
Loss of communication with
SCANport device 1 occurred.

10

SP 2 Timeout
Loss of communication with
SCANport device 2 occurred.

11

SP 3 Timeout
Loss of communication with
SCANport device 3 occurred.

Bit

Description

12

SP 4 Timeout
Loss of communication with
SCANport device 4 occurred.

13

SP 5 Timeout
Loss of communication with
SCANport device 5 occurred.

14

SP 6 Timeout
Loss of communication with
SCANport device 6 occurred.

15

SP Error
Too many errors on the
SCANport communication.

22

Fault Select 2

Use Fault Select 2 to specify how the drive should handle certain
conditions. Each bit matches the bit definitions of Warning
Select 2
(parameter 23). If you set a bit to 1, the drive reports a
fault when that condition occurs. If you clear a bit to 0, the drive
reports the condition based on Warning Select 2.

The bits are defined as follows:

Parameter number

22

File:group

Fault Setup:Fault Config

Parameter type

linkable destination

Display

bits

Factory default

10000000.00010001

Minimum value

00000000.00000000

Maximum value

11111111.11111111

Conversion

1 = 1

Refer to Chapter 12, Troubleshooting, for additional information.

Bit

Description

0

SpdFdbk Loss
A loss of feedback occurred.

1

InvOvtmp Pnd
An inverter overtemp is pending.

2

Reserved
Leave 0.

3

MtrOvld Pend
A motor overload is pending (I

2

T).

4

MtrOvld Trip
Motor overload trip (I

2

T)

Bit

Description

5

Mtr Stall
The motor stalled.

6

Ext Fault In
The ext input is open.

7 – 8

Reserved
Leave 0.

9

Param Limit
A parameter is out of limits

10

Math Limit
A math limit occurred.

Bit

Description

11 – 12 Reserved

Leave 0.

13

InvOvld Pend
An inverter overload is pending
(IT).

14

Reserved
Leave 0.

15

InvOvld Trip
Inverter overload trip (IT)

Advertising