100 an in 2 offset, 101 an in 2 scale, 102 ma input value – Rockwell Automation 1336E IMPACT Adjustable Frequency AC Drive User Manual V 1-4.XX User Manual

Page 232: 103 ma input offset, 104 ma input scale, 105 an out 1 value

Advertising
background image

11-34

Parameters

100

An In 2 Offset

Use An In 2 Offset to set the offset applied to the raw analog
value of analog input 2 before the scale factor is applied. This lets
you shift the range of the analog input.

Parameter number

100

File:group

Interface/Comm:Analog Inputs

Parameter type

linkable destination

Display

±x.xxx volts

Factory default

0.000 volts

Minimum value

-19.980 volts

Maximum value

+19.980 volts

Conversion

205 = 1.000

101

An In 2 Scale

Use An In 2 Scale to set the scale factor or gain for analog
input 2. The value of analog input 2 is converted to +2048 and
then the scale is applied. This provides an effective digital range
of

±32767.

Parameter number

101

File:group

Interface/Comm:Analog Inputs

Parameter type

linkable destination

Display

±x.xxx

Factory default

+2.000

Minimum value

-16.000

Maximum value

+16.000

Conversion

2048 = 1.000

102

mA Input Value

Use mA Input Value to view the converted analog value of the
milli amp input.

Parameter number

102

File:group

Interface/Comm:Analog Inputs

Parameter type

source

Display

±x

Factory default

not applicable

Minimum value

-32767

Maximum value

+32767

Conversion

1 = 1

103

mA Input Offset

Use mA Input Offset to set the offset applied to the raw analog
value of the milli amp input before the scale factor is applied. This
lets you shift the range of the analog input.

Parameter number

103

File:group

Interface/Comm:Analog Inputs

Parameter type

linkable destination

Display

±x.xxx mA

Factory default

+0.000 mA

Minimum value

-32.000 mA

Maximum value

+32.000 mA

Conversion

128 = 1.000

104

mA Input Scale

Enter the scale factor or gain for the milli amp input. The milli amp
input is converted to +2048 and then the scale is applied. This
provides an effective digital range of

±32767.

Parameter number

104

File:group

Interface/Comm:Analog Inputs

Parameter type

linkable destination

Display

±x.xxx

Factory default

+2.000

Minimum value

-16.000

Maximum value

+16.000

Conversion

2048 = 1.000

105

An Out 1 Value

Use An Out 1 Value to convert a +32767 digital value to a +10
volt output. This is the value of the analog output number 1.

Parameter number

105

File:group

Interface/Comm:Analog Outputs

Parameter type

linkable destination

Display

±x

Factory default

+0

Minimum value

-32767

Maximum value

+32767

Conversion

1 = 1

Advertising