11-55

185

Notch Filtr Freq

1

Use Notch Filtr Freq to set the center frequency for an optional
2-pole notch filter. To enable the notch filter, you need to set Fdbk
Filter Sel
(parameter 65) to 4.

1 Notch Filtr Freq was added in Version 2.xx.

Parameter number

185

File:group

Control:Speed Feedback

Parameter type

linkable destination

Display

x.x Hz

Factory default

135.0 Hz

Minimum value

5.0 Hz

Maximum value

135.0 Hz

Conversion

8 = 1

Refer to the Torque Reference Overview in Appendix B, Control
Block Diagrams
, f
or more information about the notch filter.

186

Notch Filtr Q

1

Use Notch Filtr Q to set the quality factor, or Q, for the 2-pole
notch filter. To enable the notch filter, you need to set Fdbk Filter
Sel
(parameter 65) to 4.

1 Notch Filtr Q was added in Version 2.xx.

Parameter number

186

File:group

Control:Speed Feedback

Parameter type

linkable destination

Display

x

Factory default

50

Minimum value

2

Maximum value

500

Conversion

1 = 1

Refer to the Torque Reference Overview in Appendix B, Control
Block Diagrams
, f
or more information about the notch filter.