217 fstar t speed, 218 reserved, 219 pwrup flt status – Rockwell Automation 1336E IMPACT Adjustable Frequency AC Drive User Manual V 1-4.XX User Manual

Page 268: 220 ncfg flt status

Advertising
background image

11-70

Parameters

217

Fstart Speed

1

Use Fstart Speed to set the start point at which the speed search
begins. This parameter is only active when operating in Fstart
Select
mode 2 (Speed Param).

To maximize reconnect performance, always set the Fstart
Speed
slightly greater than the expected reconnect motor speed.

1 Fstart Speed was added in Version 3.xx.

Parameter number

217

File:group

Application: Flying Start

Parameter type

linkable destination

Display

x.x RPM

Factory default

+ base motor speed rpm

Minimum value

Rev Speed Limit (Param 40)

Maximum value

Forward Speed Limit (Param 41)

Conversion

+4096 = base motor speed

Refer to Chapter 9, Applications, for more information.

218

Reserved

Leave this parameter set to 0.

Parameter number

218

File:group
Parameter type
Display
Factory default
Minimum value
Maximum value
Conversion

219

PwrUp Flt Status

1

PwrUp Flt Status indicates that a fault condition has been
detected during power up or reset of the drive. When a bit is “1”,
the condition is true; otherwise, the condition is false.

1 PwrUp Flt Status was added in Version 3.xx.

Parameter number

219

File:group

Monitor: Fault Status

Parameter type

source

Display

Bits

Factory default

0000 0000 0000 0000

Minimum value

0000 0000 0000 0000

Maximum value

1111 1111 1111 1111

Conversion

1 = 1

Bit

Condition

0

CP EPROM

1

CP Int RAM

2

CP Ext RAM

3

CP Stack Ram

4

CP MBI

5

Reserved

Bit

Condition

6

Reserved

7

Reserved

8

VP EPROM

9

VP Int Ram

10

VP Ext Ram

11

VP Stack RAM

Bit

Condition

12

VP MBI

13

Reserved

14

EE Checksum

15

EE R/W

220

Ncfg Flt Status

1

Ncfg Flt Status indicates that a fault condition in the drive
CANNOT be configured as a warning. When a bit is “1”, the
condition is true; otherwise, the condition is false. Bits 0 – 3 are
detected by hardware. Bits 4 – 15 are detected are detected by
software.

1 Ncfg Flt Status was added in Version 3.xx.

Parameter number

220

File:group

Monitor: Fault Status

Parameter type

source

Display

Bits

Factory default

0000 0000 0000 0000

Minimum value

0000 0000 0000 0000

Maximum value

1111 1111 1111 1111

Conversion

1 = 1

Bit

Condition

0

Bus Overvolt

1

Trans Desat

2

Ground Flt

3

IOC

4

VP Handshake

5

Diff SW Ver

Bit

Condition

6

Dr Type Dif

7

III Drv Type

8

CP Handshake

9

Abs overspd

10

+/- 15v Tol

11

Auto/Diag

Bit

Condition

12

Inv Temp Trp

13

Task Overrun

14

Ill Interrupt

15

Mode Timeout

Advertising