270 step 8 speed, 271 step 8 value, 272 step 8 type – Rockwell Automation 1336E IMPACT Adjustable Frequency AC Drive User Manual V 1-4.XX User Manual

Page 278: 273 step 9 speed, 274 step 9 value, 275 step 9 type

Advertising
background image

11-80

Parameters

270

Step 8 Speed

Parameter 270 sets the rpm value for this step. (Scaling: 4096 =
Base Speed)

Parameter number

270

File:group

Profile Test Data

Parameter type

Setup

Display

+/- x.x rpm

Factory default

+0.0 rpm

Minimum value

-8 x base speed

Maximum value

+8 x base speed

Conversion

4096 = Base Motor Speed

271

Step 8 Value

Parameter 271 sets the time in seconds for time steps, the
counts in units for encoder steps, and the TB3 input to trigger on
for TB Input steps. Scaling:

Time Step: 10 x desired value (10 = 1.0 sec)
Encoder Step: 10 = 1.0 units
TB Input Step: dependent on [L Option Mode Sel]. See P241

Parameter number

271

File:group

Profile Test Data

Parameter type

Setup

Display

x.xS, x, x.x units

Factory default

0.0,0, 0.0

Minimum value

0.0,0, 0.0

Maximum value

3276.7, 5, 3276.7

Conversion

10=1.0 sec., x TBin, 10 = 1 unit

272

Step 8 Type

Parameter 272 selects the type of step to be used

0 = Not Used (This forces an End Action)
1 = Time Step, operate at speed shown in P270 for time in P271.
2 = TB3 Input Step, operate at speed shown in P270 until this
input goes true.
3 = Encoder Step, operate at speed shown in P270 for units in
P271.

Parameter number

272

File:group

Profile Test Data

Parameter type

Setup

Display

x

Factory default

0

Minimum value

0

Maximum value

3

Conversion

273

Step 9 Speed

Parameter 273 sets the rpm value for this step. (Scaling: 4096 =
Base Speed)

Parameter number

273

File:group

Profile Test Data

Parameter type

Setup

Display

+/- x.x rpm

Factory default

+0.0 rpm

Minimum value

-8 x base speed

Maximum value

+8 x base speed

Conversion

4096 = Base Motor Speed

274

Step 9 Value

Parameter 274 sets the time in seconds for time steps, the
counts in units for encoder steps, and the TB3 input to trigger on
for TB Input steps. Scaling:

Time Step: 10 x desired value (10 = 1.0 sec)
Encoder Step: 10 = 1.0 units
TB Input Step: dependent on [L Option Mode Sel]. See P241

Parameter number

274

File:group

Profile Test Data

Parameter type

Setup

Display

x.xS, x, x.x units

Factory default

0.0,0, 0.0

Minimum value

0.0,0, 0.0

Maximum value

3276.7, 5, 3276.7

Conversion

10=1.0 sec., x TBib, 10 = 1 unit

275

Step 9 Type

Parameter 275 selects the type of step to be used

0 = Not Used (This forces an End Action)
1 = Time Step, operate at speed shown in P273 for time in P274.
2 = TB3 Input Step, operate at speed shown in P273 until this
input goes true.
3 = Encoder Step, operate at speed shown in P273 for units in
P274.

Parameter number

275

File:group

Profile Test Data

Parameter type

Setup

Display

x

Factory default

0

Minimum value

0

Maximum value

3

Conversion