Setting up the analog i/o parameters for scanport – Rockwell Automation 1336E IMPACT Adjustable Frequency AC Drive User Manual V 1-4.XX User Manual

Page 138

Advertising
background image

8-14

Using the SCANport Capabilities

Setting Up the Analog I/O
Parameters for SCANport

The following figure shows the six SCANports that are available for
use with the SCANport analog I/O and the drive parameters that you
can use to control this data.

This message:

Lets you:

Continuous Parameter Value Read

Read a continuous list of parameters beginning with the starting parameter number.

Continuous Parameter Value Write

Write to a continuous list of parameters beginning with the starting parameter number.

Scattered Parameter Value Read

Read a scattered list of parameters.

Scattered Parameter Value Write

Write to a scattered list of parameters and return the status of each parameter.

Continuous Parameter Link Read

Read a continuous list of links beginning with the starting parameter number.

Continuous Parameter Link Write

Write a continuous list of links beginning with the starting parameter number.

Scattered Parameter Link Read

Read a scattered list of parameter links.

Scattered Parameter Link Write

Write a scattered list of parameter links.

Read Product Number

Request the product number from a device.

Product Text String Read

Request the product text from a device.

Last Parameter Number Read

Request the last parameter number.

EE Command Write

Activate the specified EE function.

Read Full Parameter

Request all known attributes for the requested parameters.

Parameter Value Read

Request the value for a specific parameter.

Parameter Value Write

Write a value to a specific parameter.

Fault Command Write

Clear faults, clear the fault queue, and reset.

Fault Queue Size

Read the number of fault entries allowed in the fault queue.

Trip Fault Read

Request which fault queue entry tripped the drive.

Fault Queue Entry Read Full

Read the contents of the specified fault queue entry.

Warning Command Write

Clear faults and clear the warning queue.

Warning Queue Size

Read the number of fault entries allowed in the warning queue.

Warning Queue Entry Read Full

Read the contents of the specified warning queue entry.

Link Command Write

Clear all links.

Read Parameter Link

Request the parameter link information for a specific parameter.

Write Parameter Link

Write the parameter link information for a specific parameter.

Product Diagnostic Value

Access a simple parameter link checksum.

file:

Interface/Comm

group:

SCANport Analog

1
2
3
4
5
6

SP An In1 Sel (Par 133)

139

134

SP An In1 Value

1
2
3
4
5
6

SP An Output

SP An In1 Scale (Par 135)

SP An In2 Sel (Par 136)

137

SP An In2 Value

SP An In2 Scale (Par 138)

1
2
3
4
5
6

Advertising