Parameters

196

Drive/Inv Sts 2

1

Use Drive/Inv Sts 2 to view the status/conditions within the drive.
When a bit is set (1), the corresponding condition in the drive is
true.

1 Drive/Inv Sts 2 was added in Version 2.xx.

When set, the bits are defined as the following:

Parameter number

196

File:group

Monitor:Drive/Inv Status

Parameter type

source

Display

bits

Factory default

not applicable

Minimum value

00000000.00000000

Maximum value

11111111.11111111

Conversion

1 = 1

Bit

Description

0

Flux Ready
The motor is ready to be fluxed
up.

1

Flux Up
The motor is fluxed up.

2

DC Braking
DC braking is currently being
used.

3

Reserved
Leave 0.

4

Bus Ridethru
The drive is in a bus ridethrough
condition.

5

Jogging
The drive is jogging.

Bit

Description

6

Searching
Flying start is syncing with motor.

7

Enc TrimLoss
Indicates encoder loss when
using Encoder switchover mode

8

At Limit
The motor is at the At Limit set
point.

9

Func Output
Function Output 1
(parameter 213) and/or Function
Output 2
(parameter 214) is non-
zero.

10 – 11 Reserved

Leave 0.

Bit

Description

12

Relay Setpt1
Relay 1 has reached Relay
Setpoint 1
(parameter 115).

13

Relay Setpt2
Relay 2 has reached Relay
Setpoint 2
(parameter 188).

14

Relay Setpt3
Relay 3 has reached Relay
Setpoint 3
(parameter 190).

15

Relay Setpt4
Relay 4 has reached Relay
Setpoint 4
(parameter 192).

197

Logic Cmd Input

1

Use Logic Cmd Input to change the logic evaluation block. The
bits that you change here are reflected in Logic Input Sts
(parameter 14).

1 Logic Cmd Input was added in Version 2.xx.

The bits are defined as follows:

Parameter number

197

File:group

none

Parameter type

linkable destination

Display

bits

Factory default

00000000.00000000

Minimum value

00000000.00000000

Maximum value

11111111.11111111

Conversion

1 = 1

Bit

Description

0

Normal Stop
A ramp stop is selected.

1

Start
A start is in progress.

2

Jog 1
A jog 1 is in progress.

3

Clear Fault
A clear fault is in progress.

4

Forward
A forward was commanded.

Bit

Description

5

Reverse
A reverse was commanded.

6

Jog 2
A jog 2 is in progress.

7

Cur Lim Stop
A current limit stop is
selected.

8

Coast Stop
A coast stop is selected.

9

Spd Ramp Dis
Ramps are disabled.

Bit

Description

10

Flux Enable
Flux is enabled.

11

Process Trim
Process trim is enabled.

12

Speed Ref A

13

Speed Ref B

14

Speed Ref C

15

Reset Drive
The drive has been
commanded to reset.

C B A
0 0 0 No Charge
0 0 1 Speed Ref 1
0 1 0 Speed Ref 2
0 1 1 Speed Ref 3
1 0 0 Speed Ref 4
1 0 1 Speed Ref 5
1 1 0 Speed Ref 6
1 1 1 Speed Ref 7