Rockwell Automation 1336E IMPACT Adjustable Frequency AC Drive User Manual V 1-4.XX User Manual

Page 374

Advertising
background image

B-36

Control Block Diagrams

Measuring the Inertia

To measure the inertia, the speed loop auto-tune test:

1. Applies the amount of torque specified in Autotune Torque

(parameter 164) to the motor.

2. Ramps the speed up to the speed specified in Autotune Speed

(parameter 165).

3. Decreases the speed down to 0.

4. Measures the slope of the increase and decrease to determine the

inertia.

Once the torque is applied, how the test measures the inertia depends
on whether bit 10 of Bus/Brake Opts (parameter 13) is set.

If bit 10 is set, the speed is ramped down to 0 after the motor reaches
the speed specified in Autotune Speed. At the same time, the torque
becomes a negative value and remains negative until the speed
reaches 0. This is shown as:

If bit 10 is not set, the speed coasts down to 0 after the motor reaches
the speed specified in Autotune Speed. The torque also becomes 0 at
this point. This is shown as:

file:

Application

group:

Bus Reg/Control

Speed

Time

Autotune Speed

(parameter 165)

Dwell
Time

Slope used to find inertia

0

0

Torque

Time

Autotune Torque

(parameter 164)

Dwell
Time

0

Autotune Torque

(parameter 164)

With a brake:

Speed

Time

Autotune Speed
(parameter 165)

Dwell
Time

Slope used to find inertia

0

0

Torque

Time

Autotune Torque
(parameter 164)

Dwell
Time

0

With no brake:

0

Advertising