11-19

34

Speed Ref 5

Enter the speed reference that the drive should use when speed
reference 5 is selected in Logic Input Sts (parameter 14).

Parameter number

34

File:group

Control:Speed Reference

Parameter type

linkable destination

Display

±x.x rpm

Factory default

+0.0 rpm

Minimum value

-8 x base motor speed rpm

Maximum value

+8 x base motor speed rpm

Conversion

4096 = base motor speed

35

Speed Ref 6

Enter the speed reference that the drive should use when speed
reference 6 is selected in Logic Input Sts (parameter 14).

Parameter number

35

File:group

Control:Speed Reference

Parameter type

linkable destination

Display

±x.x rpm

Factory default

+0.0 rpm

Minimum value

-8 x base motor speed rpm

Maximum value

+8 x base motor speed rpm

Conversion

4096 = base motor speed

36

Speed Ref 7

Enter the speed reference that the drive should use when speed
reference 7 is selected in Logic Input Sts (parameter 14).

Parameter number

36

File:group

Control:Speed Reference

Parameter type

linkable destination

Display

±x.x rpm

Factory default

+0.0 rpm

Minimum value

-8 x base motor speed rpm

Maximum value

+8 x base motor speed rpm

Conversion

4096 = base motor speed

37

Speed Scale 7

Enter the gain multiplier used to scale Speed Ref 7
(parameter 36).

Parameter number

37

File:group

Control:Speed Reference

Parameter type

linkable destination

Display

±x.xxxx

Factory default

+1.0000

Minimum value

-3.9999

Maximum value

+3.9999

Conversion

8192 = 1.0000

38

Jog Speed 1

Enter the speed reference that the drive should use when Jog 1
is selected in Logic Input Sts (parameter 14).

Parameter number

38

File:group

Control:Speed Reference

Parameter type

linkable destination

Display

±x.x rpm

Factory default

+100.0 rpm

Minimum value

-8 x base motor speed rpm

Maximum value

+8 x base motor speed rpm

Conversion

4096 = base motor speed

39

Jog Speed 2

Enter the speed reference that the drive should use when Jog 2
is selected in Logic Input Sts (parameter 14).

Parameter number

39

File:group

Control:Speed Reference

Parameter type

linkable destination

Display

±x.x rpm

Factory default

+0.0 rpm

Minimum value

-8 x base motor speed rpm

Maximum value

+8 x base motor speed rpm

Conversion

4096 = base motor speed

Advertising