235 profile enable, 236 profile status, 237 error trim gain – Rockwell Automation 1336E IMPACT Adjustable Frequency AC Drive User Manual V 1-4.XX User Manual

Page 272: 238 end action sel, 239 end action speed

Advertising
background image

11-74

Parameters

235

Profile Enable

Profile Enable is the command word for speed profiling.

Bit 0 - Sets the home position and must be set to 1 for profiling to
operate.
Bit 1 - Must be set to run the sequence of the speed profile that is
programmed.
Bit 2 - When set to 1, causes the transition from one step to the
next to be held until the bit is set to 0.
Bit 3 - Is used with the sequential encoder steps and prevents the
speed from dropping to zero at the end of each step.
Bits 4-7 - Reserved

Parameter number

235

File:group

Profile Command

Parameter type

Setup

Display

Bits

Factory default

0

Minimum value

000Fhex

Maximum value))Fhex
Conversion

236

Profile Status

Profile Status indicates the state of the profiling routine.

Bits 0-4 - Indicate the binary value of active step, 1-16.
Bit 5 - Enabled when set to 1.
Bit 6 - Run Sequence on when set to 1. This bit clears when
sequence is complete.
Bit 7- Hold is active when set to 1.
Bit 8 - Encoder Velocity Blend mode selected when set to 1.

Parameter number

236

File:group

Profile Command

Parameter type

Setup

Display

Bits

Factory default

0

Minimum value

0000hex

Maximum value

001Fhex

Conversion

237

Error Trim Gain

Sets the gain for the speed profiling control in a range from 0.5 -
16.0. When sending values over a network connection, the
scaling is 128 = 1.0

Parameter number

237

File:group

Profile Command

Parameter type

Setup

Display

x.x units

Factory default

2

Minimum value

0.5

Maximum value

16.0

Conversion

128 = 1.0

238

End Action Sel

Parameter 238 can be used to select how the end of the run
sequence is accomplished.

0 = Stop - Command Zero Speed

1 = Go to Step, uses P240 to determine which step to proceed to
when the end is reached.

2 = TB3 Input, uses P241 to select which TB3 terminal to use.

3 = Compare, uses P242 as the comparison value.

4 = Encoder Home, goes to the home position determined when
function enabled.

Parameter number

238

File:group

Profile End Actions

Parameter type

Setup

Display

x

Factory default

0

Minimum value

0

Maximum value

4

Conversion

239

End Action Speed

Parameter 239 sets the speed for the end action.

4096 = Base Speed

Parameter number

239

File:group

Profile End Actions

Parameter type

Setup

Display

+/- x.x rpm

Factory default

+0.0 rpm

Minimum value

-8 x base speed

Maximum value

+8 x base speed

Conversion

4096 = base speed

Advertising