133

SP An In1 Select

Use SP An In1 Select to select which SCANport analog device is
used in SP An In1 Value (parameter 134).

Parameter number

133

File:group

Interface/Comm:SCANport Analog

Parameter type

linkable destination

Display

x

Factory default

1

Minimum value

1

Maximum value

6

Conversion

1 = 1

Value

Description

1

SP 1
Use SCANport device 1.

2

SP 2
Use SCANport device 2.

Value

Description

3

SP 3
Use SCANport device 3.

4

SP 4
Use SCANport device 4.

Value

Description

5

SP 5
Use SCANport device 5.

6

SP 6
Use SCANport device 6.

134

SP An In1 Value

Use SP An In1 Value to view the analog value of the SCANport
device selected in SP An In1 Select (parameter 133). You need
to link SP An In1 Value to a parameter such as Speed Ref 1
(parameter 29).

Parameter number

134

File:group

Interface/Comm:SCANport Analog

Parameter type

source

Display

±x

Factory default

not applicable

Minimum value

-32767

Maximum value

+32767

Conversion

1 = 1

135

SP An In1 Scale

Use SP An In1 Scale to scale SP An In1 Value (parameter 134).

Parameter number

135

File:group

Interface/Comm:SCANport Analog

Parameter type

linkable destination

Display

±x.xxx

Factory default

+0.125

Minimum value

-1.000

Maximum value

+1.000

Conversion

32767 = 1.000

136

SP An In2 Select

Use SP An In2 Select to select which SCANport analog device is
used in SP An In2 Value (parameter 137).

Parameter number

136

File:group

Interface/Comm:SCANport Analog

Parameter type

linkable destination

Display

x

Factory default

6

Minimum value

1

Maximum value

6

Conversion

1 = 1

Value

Description

1

SP 1
Use SCANport device 1.

2

SP 2
Use SCANport device 2.

Value

Description

3

SP 3
Use SCANport device 3.

4

SP 4
Use SCANport device 4.

Value

Description

5

SP 5
Use SCANport device 5.

6

SP 6
Use SCANport device 6.

137

SP An In2 Value

Use SP An In2 Value to view the analog value of the SCANport
device selected in SP An In2 Select (parameter 136). You need
to link SP An In2 Value to a parameter such as Speed Ref 1
(parameter 29).

Parameter number

137

File:group

Interface/Comm:SCANport Analog

Parameter type

source

Display

±x

Factory default

not applicable

Minimum value

-32767

Maximum value

+32767

Conversion

1 = 1