A, figure, Using the l option 5-5, Table 5.a available control functions – Rockwell Automation 1336E IMPACT Adjustable Frequency AC Drive User Manual V 1-4.XX User Manual

Page 87

Advertising
background image

Using the L Option

5-5

Table 5.A shows the available combinations. Figure 5.1 and
Figure 5.2 also show the available combinations.

Table 5.A
Available Control Functions

Control
Function

Input Mode

1

2

3

4

5

6

7

8

9

10 11 12 13 14 15 16 17 18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

1st Accel

1st Decel

2nd/1st Decel

1

2nd Accel

2nd Decel

Common

● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●

Enable

● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●

Flux Enable

Forward

● ●

Jog

● ●

Local

MOP Dn

2

● ●

MOP Up

2

● ●

Not Ext Fault

● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●

Not Stop, Clr
Flt

● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●

Proc Trim

Ramp

Reset

Reverse

● ●

Rev/Fwd

1,3

● ● ● ● ●

● ●

Run Fwd

● ● ● ● ●

Run Rev

● ● ● ● ●

Spd Sel 1

4

● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●

Spd Sel 2

4

● ● ● ● ● ● ● ●

● ● ● ● ● ● ●

Spd Sel 3

4

● ●

● ●

● ●

Spd/Trq 1

5

● ●

Spd/Trq 2

5

● ●

Spd/Trq 3

5

● ●

Start

● ● ● ● ● ● ● ● ● ●

● ● ● ● ● ●

Status

Stop Type

1

Profile Enable

Step Trigger

Run Sequence

Position Hold

1 The L Option uses the first function (such as 1st Decel or Rev) when input is applied and the second function (such as 2nd Decel or Fwd)

when input is not applied.

2 In modes 5, 9, 10, and 15, the MOP value is not reset to 0 when you stop. In modes 27, 28, 29, and 30, the MOP value is reset to 0 when you stop.

3 The L Option has ownership of direction. No other device on SCANport can control the direction.

4 The L Option has ownership of reference if all three selects are not available.

5 The L Option controls Spd/Trq Mode Sel (parameter 68).

NOTE: All Functions are enabled when input is applied and disabled when not applied.