Rockwell Automation 1336E IMPACT Adjustable Frequency AC Drive User Manual V 1-4.XX User Manual
Page 186
Advertising
10-16
Using the Function Block
Figure 10.19
Example of a Simple Shuttle
To set up the function block for this example, you would need to enter
the values shown in Figure 10.20.
A
inc
Speed Ref 2
50 rpm
B
C
D
E
F
G
H
inc
Speed Ref 3
100 rpm
inc
Speed Ref 4
500 rpm
inc
Speed Ref 5
250 rpm
inc
Speed Ref 6
125 rpm
inc
Speed Ref 7
40 rpm
inc
Speed Ref 7
40 rpm
inc
Speed Ref 6
125 rpm
inc
Speed Ref 5
250 rpm
inc
Speed Ref 4
500 rpm
inc
Speed Ref 3
100 rpm
inc
Speed Ref 2
50 rpm
Speed Ref 1
25 rpm
Speed Ref 1
25 rpm
Speed
0
100
200
300
400
500
Speed
0
100
200
300
400
500
A
B
C
D
E
F
G
H
Advertising