129 start/stop owner – Rockwell Automation 1336E IMPACT Adjustable Frequency AC Drive User Manual V 1-4.XX User Manual

Page 240

Advertising
background image

11-42

Parameters

129

Start/Stop Owner

You can use the lower byte of Start/Stop Owner (bits 0 through 7)
to see which SCANport device(s) are presently issuing a valid
stop command. You can use the higher byte (bits 8 through 15) to
see which SCANport device(s) are presently issuing a valid start
command. You can choose between:

0 = Stop/start input not present
1 = Stop/start input present

The bits are defined as follows:

Parameter number

129

File:group

Monitor Status:SCANport Status

Interface/Comm:SCANport Status

Parameter type

source

Display

bits

Factory default

not applicable

Minimum value

00000000.00000000

Maximum value

11111111.11111111

Conversion

1 = 1

Refer to Chapter 8, Using the SCANport Capabilities, for more
information.

Bit

Description

0

Stop L Opt
The L Option board owns the
stop.

1

Stop SP 1
SCANport device 1 owns the
stop.

2

Stop SP 2
SCANport device 2 owns the
stop.

3

Stop SP 3
SCANport device 3 owns the
stop.

4

Stop SP 4
SCANport device 4 owns the
stop.

5

Stop SP 5
SCANport device 5 owns the
stop.

Bit

Description

6

Stop SP 6
SCANport device 6 owns the
stop.

7

Stop P197
Logic Cmd Input (parameter 197)
owns the stop.

8

Start L Opt
The L Option owns the start.

9

Start SP 1
SCANport device 1 owns the
start.

10

Start SP 2
SCANport device 2 owns the
start.

Bit

Description

11

Start SP 3
SCANport device 3 owns the
start.

12

Start SP 4
SCANport device 4 owns the
start.

13

Start SP 5
SCANport device 5 owns the
start.

14

Start SP 6
SCANport device 6 owns the
start.

15

Start P197
Logic Cmd Input (parameter 197)
owns the start.

130

Jog1/Jog2 Owner

You can use the lower byte of Jog1/Jog2 Owner (bits 0 through 7)
to see which SCANport device(s) are presently issuing a valid
jog 2 command. You can use the higher byte (bits 8 through 15)
to see which SCANport device(s) are presently issuing a valid
jog 1 command. You can choose between:

0 = Jog 1/jog 2 input not present
1 = Jog 1/jog 2 input present

The bits are defined as follows:

Parameter number

130

File:group

Monitor Status:SCANport Status

Interface/Comm:SCANport Status

Parameter type

source

Display

bits

Factory default

not applicable

Minimum value

00000000.00000000

Maximum value

11111111.11111111

Conversion

1 = 1

Refer to Chapter 8, Using the SCANport Capabilities, for more
information.

Bit

Description

0

Jog2 L Opt
The L Option board owns the
Jog2.

1

Jog2 SP 1
SCANport device 1 owns the
Jog2.

2

Jog2 SP 2
SCANport device 2 owns the
Jog2.

3

Jog2 SP 3
SCANport device 3 owns the
Jog2.

4

Jog2 SP 4
SCANport device 4 owns the
Jog2.

5

Jog2 SP 5
SCANport device 5 owns the
Jog2.

Bit

Description

6

Jog2 SP 6
SCANport device 6 owns the
Jog2.

7

Jog2 P197
Logic Cmd Input (parameter 197)
owns the Jog2.

8

Jog1 L Opt
The L Option owns the Jog1.

9

Jog1 SP 1
SCANport device 1 owns the
Jog1.

10

Jog1 SP 2
SCANport device 2 owns the
Jog1.

Bit

Description

11

Jog1 SP 3
SCANport device 3 owns the
Jog1.

12

Jog1 SP 4
SCANport device 4 owns the
Jog1.

13

Jog1 SP 5
SCANport device 5 owns the
Jog1.

14

Jog1 SP 6
SCANport device 6 owns the
Jog1.

15

Jog1 P197
Logic Cmd Input (parameter 197)
owns the Jog1.

Advertising