3.4.4 Control Signals for Direct Simple Direct

To select the mode, use Gateway Parameter Setting Tool. This is the operation method to

indicate the target position by directly inputting a value, and indicate a position number for other

operational conditions.

The settable No. of position data items is max 256 points.

The main functions of MSCON capable to control in this mode are as described in the following

table.

{

: Direct control

ٌ

: Indirect control

×: Disable

ROBO cylinder function

Simple Direct Mode

Remarks

Home-return operation

{

Positioning operation

{

For those other than the target position, it is

necessary to set the position data

Speed and

acceleration/deceleration

setting

ٌ

Pitch feeding (Incremental)

ٌ

Pressing operation

ٌ

Speed change during

movement

ٌ

Operation at different

acceleration and

deceleration

ٌ

These items must be set in the position data

table.

Pause

{

Zone signal output

{

PIO pattern selection

×



(1) PLC Address Composition

(m is PLC input and output top word address for each axis number)

PLCĺMSCON (PLC Output)

MSCONĺPLC (PLC Input)

Target Position

m to m+1

Current Position

m to m+1

Specified Position No.

m+2

Completed Position No.

(Simple Alarm Code)

m+2

Control Signal

m+3

Status Signal

m+3

[Refer to Section 3.4.2 for the address maps for each Fieldbus.]

This mode is not applicable for CompNet and MECHATROLINK specifications.