Alarm

Code

Alarm

Level

Alarm Name

Cause/Treatment

093

Operation

release

PWRT signal detection

in incomplete home

return

Cause

: The current position write signal PWRT was input in

the teaching mode of PIO pattern 1 when home

return was not yet completed.

Treatment : Input the HOME signal first to perform home return,

and then input the PWRT signal after confirming

that the home return has completed (HEND output

signal is ON).

0A1

Cold start

Parameter data error

Cause

: The data input range in the parameter area is not

appropriate. This error occurs when the magnitude

relationship is apparently inappropriate such as

when 300mm was incorrectly input as the value of

the soft limit negative side while the value of the soft

limit positive side was 200.3mm.

Treatment : Change the value to the appropriate one.