7 wiring layout of field network connector – IAI America MSCON User Manual
Page 64
![background image](/manuals/350327/64/background.png)
Chapter 2 Wiring
56
2.3.7 Wiring Layout of Field Network Connector
Check the instruction manuals for each Field Network master unit and mounted PLC for the
details.
1) DeviceNet Type
Shield
BL (CAN L)
RD (V+)
WT (CAN H)
BK (V-)
DeviceNet
Connector Model
Remarks
Cable Side SMSTB2.5/5-ST-5.08 AU
Enclosed in standard package
Manufactured by PHOENIX
CONTACT
Controller
Side
MSTBA2.5/5-G-5.08 ABGY AU
Pin No.
Signal Name
Contents
Applicable Cable
1
V- (BK)
Power Supply Cable
Negative Side
2
CAN L (BL)
Communication Data Low
Side
3
Shield (None)
Shield
4
CAN H (WT)
Communication Data High
Side
5
V+ (RD)
Power Supply Cable
Positive Side
DeviceNet
Dedicated Cable
(Note): Connect a terminal resistor (121:) between CAN L and CAN H
to the end of the network. [Refer to 2.2 [8] Field Network Circuit
(For Field network Type)]
Blue
Black
Red
White
Front view of
connector on
controller side