Control and functions of Input and output signals of Modes other than Remote I/O Mode

Power Supply and Cutof

f

162

First-Order Lag Filter

This describes much gentle acceleration/deceleration curve than that for the linear

acceleration/deceleration (trapezoid pattern).

Use it when it is not desired to give any slight vibration to the work in acceleration/deceleration

operation.

Velocity

Time

(Note) The first-order lag degree set using the parameter No.55 “Position Command Primary

Filter Time Constant”. The minimum input unit is 0.1msec and setting range is from “0.0”

to “100.0”.

When it is set to “0”, the first-order lag filter is disabled.

However, the setting is not reflected on the jog operation or inching operation performed

using the personal computer or teaching pendant.




(23) Servo gain parameter set Select (GSL0, GSL1) PLC Output Signal

Operation

Mode

Positioner 1

Simple Direct

Direct numeric

specification

Direct numeric

specification 2

Positioner 2

Positioner 3

{

: Equipped

× : Not equipped

Ч

Ч

{

{

Ч

Ч

By registering four sets out of the following servo gain parameters (6 sets) in advance, an

operation is available with the selected set for each position movement.

See the parameters for the details.

GSL1

GSL0

Function

Remarks

OFF

OFF

Parameter Set 0 Select

Set in delivery

OFF

ON

Parameter Set 1 Select

ON

OFF

Parameter Set 2 Select

ON

ON

Parameter Set 3 Select

(24) Incremental command (INC) PLC Output Signal

Operation

Mode

Positioner 1

Simple Direct

Direct numeric

specification

Direct numeric

specification 2

Positioner 2

Positioner 3

{

: Equipped

× : Not equipped

Ч

Ч

{

{

Ч

Ч

When the movement command is issued while this signal is turned ON, the actuator is moved

to the position expressed as the value input in the PLC's target position register based on the

current position. (elative movement)

When this signal is turned OFF, the actuator is moved to the position expressed as the value

set in the PLC's target position register.