IAI America MSCON User Manual

Page 275

Advertising
background image

Chapter 7 Parameter

267

[37] S-motion rate (Parameter No.56)

No.

Name

Symbol

Unit

Input Range

Default factory

setting

56 S-motion Rate

SCRV

%

0 to 100

0

This parameter is used when the value in the “Acceleration/deceleration mode” field of the

position table is set to “1 (S-motion)”.

This enables to ease the impact at acceleration and deceleration without making the takt time

longer.

The S-motion is a sine curve that has the acceleration time as 1 cycle.

The level of its swing width can be set by this parameter.

Setting of Parameter No.56 [%] Level of swing width

0 [Set in delivery]

No S-motion (Dotted line shown in the image below)

100

Sine curve swing width × 1 (Double-dashed line shown in the image below)

50

Sine curve swing width × 0.5 (Dashed line shown in the image below)

10

Sine curve swing width × 0.1 (Solid line shown in the image below)

Velocity

Time

0

Setting: 10
Setting: 50

Setting: 100

Within 2 seconds

(Caution 3))

 

Caution:

1) If the S-motion is specified in acceleration/deceleration mode, executing position

command or direct value command while the actuator is moving causes an actuator to

move along the trapezoid pattern.

To change a speed during operation, be sure to specify such a position command

while the actuator is in pause state.

2) In the index mode of rotary actuator, the S-motion control is disabled. If S-motion

acceleration/deceleration is specified, the trapezoid pattern is used in

acceleration/deceleration mode.

3) If acceleration time or deceleration time exceeds 2 seconds, do not specify S-motion

control. The actuator will be the trapezoid operation.

4) Do not perform temporary stop during acceleration or deceleration. The speed change

(acceleration) may cause the dangerous situation.

Velocity

Time

Swing width

Acceleration time

0

Advertising