IAI America MSCON User Manual

Page 123

Advertising
background image

3.4 Fieldbus

Type
Address Map

115

Signal Type

Bit

Symbol

Contents

Details

b15

BKRL

Brake release

ON: Brake release, OFF: Brake activated

3.7 (17)

b14

INC

Incremental command

ON: Relative position movement command,

OFF: Absolute position movement command

3.7 (26)

b13

DIR

Push direction specification

ON: Movement against home position,

OFF:Movement toward home position

3.7 (19)

b12

PUSH

Push-motion specification

ON: Pressing operation, OFF: Positioning operation

3.7 (18)

Select the servo gain parameter set

number to be used

GSL1

GSL0

Gain Set

b11

GSL1

Servo Gain

Parameter

Set Select 1

OFF

OFF

Gain Parameter

Set 0 Select

OFF

ON

Gain Parameter

Set 1 Select

ON

OFF

Gain Parameter

Set 2 Select

ON

ON

Gain Parameter

Set 3 Select

b10

GSL0

Servo Gain

Parameter

Set Select 0

3.7 (25)

Select the anti-vibration control mode

number to be used

NTC1

NTC0

Anti-Vibration

Control Mode

b9

NTC1

Anti-Vibration

Control Mode

Select 1

OFF

OFF

Anti-vibration

control not to be

used

OFF

ON

Parameter Set 1

Select

ON

OFF

Parameter Set 2

Select

ON

ON

Parameter Set 3

Select

b8

NTC0

Anti-Vibration

Control Mode

Select 1

3.7 (23)

Select the acceleration/deceleration

mode number to be used

MOD1 MOD0

Acceleration /

deceleration mode

b7

MOD1

Acceleration/

Deceleration

Mode

Select 1

OFF

OFF

Trapezoid pattern

control selected

OFF

ON

S-shaped motion

control selected

ON

OFF

Primary delay

filter control

selected

b6

MOD0

Acceleration/

Deceleration

Mode

Select 0

3.7 (24)

b5

Unavailable

b4

SON

Servo ON Command

ON: Servo ON, OFF: Servo OFF

3.7 (5)

b3

RES

Reset

A reset is performed when this signal turns ON.

3.7 (4)

b2

STP

Pause

ON: Pause, OFF: Pause release

3.7 (10)

b1

HOME

Home return

Home-return command with this signal ON, command

carried on till complete even if the signal is turned OFF

on the way

3.7 (6)

P

LC

O

ut

pu

t

Control Signal

b0

CSTR

Positioning start

Movement command executed with this signal ON,

command carried on till complete even if the signal is

turned OFF on the way

3.7 (7)