IAI America MSCON User Manual

Page 57

Advertising
background image

Chapter 2 Wiring

49

2.3.2 Wiring Layout of System I/O Connector

This consists of the emergency stop input and cable terminals for the operation mode

(AUTO/MANU) switch.

Strip the sheath of the applicable wires for 10mm and insert them to the connector. Push a

protrusion beside the cable inlet with a small slotted screwdriver to open the inlet. Once the

cable is inserted, take the slotted screwdriver off the protrusion to fix the cable to the terminal.


System I/O

Connector

Model

Remarks

Cable Side

FMCD1.5/4-ST-3.5

Enclosed in standard

package

Manufactured by PHOENIX

CONTACT

Controller Side MCDN1.5/4-G1-3.5P26THR

Pin

No.

Signal

Name

Contents

Applicable

Cable

1 EMG+

+24V power output for emergency stop

2 S2

For external emergency stop signal input

3 S1

For external emergency stop signal output

4 EMG-

Emergency-stop input

5 A/M+

+24V output for operation mode

(AUTO/MANU) switchover

6 A/M-

Operation mode (AUTO/MANU)

switchover signal input

KIV1.25 to

0.2mm

(AWG16 to

24)

7 NC
8 NC

Connection is not required

Accessory

Connector

(Plug)

Emergency Stop

Circuit

Front view of

connector on

controller side

A/M-

A/M+

EMG-
S1
S2
EMG+