Chapter 7 parameter, Parameter list (continued) – IAI America MSCON User Manual

Page 260

Advertising
background image

Chapter 7 Parameter

252

Parameter List (continued)

No.

C

at

eg

or

y

Name

Symbol Unit

(Note 1)

Input Range

Default factory

setting

Relevant

sections

131 C Current Control Width

Number 2

CLP2

0 to 4

In accordance

with actuator

(Note 2)

7.2 [35]

7.3

132 C Servo Gain Number 3

PLG3

-

0 to 31

In accordance

with actuator

(Note 2)

7.2 [5]

7.3

133 C Feed Forward Gain 3

PLF3

-

0 to 100

In accordance

with actuator

(Note 2)

7.2 [41]

134 C Speed Loop Proportional

Gain 3

VLG3

-

1 to 27661

In accordance

with actuator

(Note 2)

7.2 [21]

7.3

135 C Speed Loop Integral Gain 3

VLT3

-

1 to 217270

In accordance

with actuator

(Note 2)

7.2 [22]

7.3

136 C Torque Filter Time Constant 3 TRF3

-

0 to 2500

In accordance

with actuator

(Note 2)

7.2 [23]

7.3

137 C Current Control Width

Number 3

CLP3

-

0 to 4

In accordance

with actuator

(Note 2)

7.2 [35]

7.3

138 C Servo Gain Switchover Time

Constant

GCFT

ms

10 to 2000

10

7.2 [82]

139 A Home Preset Value

PRST

mm

-9999.99 to

9999.99

In accordance

with actuator

(Note 2)

7.2 [83]

143 B Overload Level Ratio

OLWL

%

50 to 100

100

7.2 [84]

147 B Total Movement Count

Threshold

TMCT

Times

0 to 999999999

0 (Disabled)

7.2 [85]

148 B Total Operated Distance

Threshold

ODOT

m

0 to 999999999

0 (Disabled)

7.2 [86]

149 B Zone Output Changeover

FPIO

-

0: Not to change

1: To change

0

7.2 [87]

150 A Linear Absolute Home Preset

Value

LAPS

For future

extension use.

Unavailable

151 B Light Error Alarm Output

Select

FSTP

-

0: Battery voltage

drop warning

output

1: Output of

battery voltage

drop warning or

message-level

alarm

0

7.2 [89]

157 B Drive Cutoff Alarm Level

FSTP

-

0 to 2

0

7.2 [90]

158 B Enable/Disable Axis Select

ATYP

-

0: Enabled

1: Disabled

0

7.2 [91]

Note 2: The setting values vary in accordance with the specification of the actuator. At shipment, the

parameters are set in accordance with the specification.



Advertising