3.8 Control and functions of Input and output signals of Remote I/O Mode

186

[4] Pressing operation

„

Sample use

No.

Position

[mm]

Velocity

[mm/s]

Accele-

ration

[G]

Decele-

ration

[G]

Pressing

[%]

Thresh-

old

[%]

Positioning

width

[mm]

Zone+

[mm]

Zone-

[mm]

Acceleration/

Deceleration

mode

Incre-

mental

Gain

set

Stop

mode

0

1

0.00

250.00

0.20

0.20

0

0

0.10

0.00

0.00

0

0

0

0

2

100.00

250.00

0.20

0.20

50

0

50.00

0.00

0.00

0

0

0

0

(Position No.2 sets pressing operation.)

„

Control method

1) The method of controlling the pressing operation is the same as that described in [1]

Positioning except the setting of the position table. Any setting of “Pressing” in the position

table allows the pressing operation to be done. “Positioning width” is assumed as pressing

operation distance.

2) The actuator moves at the setting speed and rating torque to the position of the coordinate

set in “Position” in the similar way as normal positioning. Then the operation changes to

pressing. The moving distance in pressing is the value set in “Positioning width”. The

pressing is performed with the torque (current limit value) set in percent in “Pressing” of PIO

patterns 1 to 2 being the upper limit.

3) The control method is the same as that in [1] Positioning. However, the processing of

positioning complete signal PEND is different from that in [1] Positioning.

PEND is output when the shaft is stopped by pressing (pressing complete). If the work is not

subject to pressing (miss-pressing), the actuator moves by the value set in “Positioning

width” to stop but PEND is not turned ON.

Press-fitting process

Caulking process

Position 2

input

Start signal

input

(moving)

Move

forwarc at

low speed

without stop

Pressing to work

and stop

Pressing held by

setup pressing force

Positioning

complete

signal

output

Stop

status

Acceleration

Deceleration

2)

3)

4)

1)

Velocity

Time

Position 1

Coordinate

Value:100

2)

3)

4)

1)

5)

5)

Positioning width 50

250mm/sec

* Without contaction work

until the end of

positioning band,

positioning complete

signal is not output

Work