Chapter 7 Parameter

266

[33] Default acceleration/deceleration mode (Parameter No.52)

No.

Name

Symbol

Unit

Input Range

Default factory

setting

52 Default Acceleration/

Deceleration Mode

CTLF

-

0 to 2

0 (Trapezoid

When a target position is written to an unregistered position table, this value is automatically set

as the “Acceleration/deceleration mode” of the applicable position number.

Set Value

Description

0

Trapezoid

1

S-motion

2

Primary delay filter

[34] Default stop mode (Parameter No.53)

No.

Name

Symbol

Unit

Input Range

Default factory

setting

53 Default Stop Mode

CTLF

-

0 to 3

0 (Not applicable)

This parameter defines the power-saving function.

[Refer to Chapter 5 Power-saving Function.]

[35] Current control width number (Parameter No.54)



No.

Name

Symbol

Unit

Input Range

Default factory

setting

54 Current Control Width Number

CLPF

-

0 to 4

In accordance

with actuator


This parameter is for the manufacturer’s use only to determine the response capability of

thecurrent loop control. Therefore, do not change the settings in this parameter. If the

parameter ischanged carelessly, control safety may be adversely affected and a very

dangerous situationmay result.

[36] Position command primary filter time constant (Parameter No.55)

No.

Name

Symbol

Unit

Input Range

Default factory

setting

55 Position Command Primary Filter

Time Constant

PLPF

msec

0.0 to 100.0

0.0

This is to be used when setting the value in “Acceleration/Deceleration Mode” box in the

position table to 2 “Primary Delay Filter”.

The primary delay filter is disabled if “0” is set.

The greater the setting value is, the longer the delay is and the slower the

acceleration/deceleration is. The impact at the acceleration and deceleration will be eased, but

the takt time will become longer.

Velocity

Time